Drass Flame Sensor
- Stock: In Stock
- Brand: Drass
- Model: 97CE-06-01-01-00-00
- Dimensions: 25.00cm x 25.00cm x 20.00cm
2,200.00€
Proudly presenting the innovative Drass HUF (Hyperbaric Ultraviolet Flame) Sensor, the only flame
sensor on the market to receive IACS Class Society Type Approval for use in a hyperbaric environment.
Pressure tested up to 50 bar and able to detect a flame at 10 times the distance of standard flame
detectors, its fine tuned configuration ensures the detection of small flame inside a DDC or TUP
within a few milliseconds.
This product thereby provides ultimate reassurance for those working in
safety-critical environments.
The Drass HUF Sensor “sees” UV radiation within such a narrow band width that a single flame is
detected before it is visible to the naked eye (see graph below). What is more, the fine precision of
this UV band range prevents sun or artificial lights from creating false alerts. Upon fire recognition,
the HUF Sensor signals a change in state from normal operation (green light) to fire alert (red light)
thereby activating the alarm and fire extinguishing system, in accordance with company and HSE
regulation.
The HUF sensor is compatible with standard fire alarm panels including Consilium which are commonly
part of Drass installations and bear the IACS Class Society Type Approval Certificate. Such an integration
also ensures the immediate detection of short-circuit or cable break, thereby optimizing the system’s
safety performance.
As a natural complement to the HUF Sensors, Drass provides smoke alarms that are IACS Class Society Type Approved,
and validated by Drass under Class supervision for hyperbaric use. They can also be connected
to the Consilium Fire Alarm Panel, making the whole arrangement a single-stop solution
against flame/ smoke risks.
The HUF sensor comes in a red anodized aluminium housing with a splash proof 10-way connector
on the back of the unit. Internal electronics are encapsulated in resin thereby securing these from
environment factors including temperature
variations, moisture and dust.
A standard installation includes two Flame
Sensors for each chamber, each one
installed on the upper part of opposite
chamber walls thereby ensuring all angles
are covered. Commonly the sensors
are managed from the control room and
additional panels can be easily installed
where required, making it possible to obtain
a system which is tailored to customer
needs.
Sensors include a password protected
RS232 service connection in order to
check configuration and reconfigure desired
parameters in terms of threshold,
delay, latency. Flame Sensor is supplied with 5m cable.